Product Details:
|
| Product Name: | 48x25GE 6x100GE Data Center Switch VXLAN EVPN Low Latency 1U ToR | Application: | Data Center Spine Leaf Fabric, AI Compute And Cloud ToR |
|---|---|---|---|
| Port Configuration: | 48 X 25GE SFP28 Downlink, 6 X 100GE QSFP28 Uplink | Uplink Speed: | 100GE QSFP28, 40GE Compatible, 4 X 25GE Breakout |
| Switching Capacity: | 4 Tbit/s | Forwarding Performance: | 2000 Mpps |
| Forwarding Latency: | Under 1 Microsecond Cut-through | Overlay Protocol: | VXLAN, BGP EVPN, M-LAG |
| Form Factor: | 1U 19 Inch Rack Mount | Power And Cooling: | 1+1 Redundant AC Or DC Power, N+1 Fans, Front-to-back Airflow |
| Highlight: | 48x25GE 6x100GE Uplink Ports,VXLAN EVPN M-LAG Overlay Fabric,1U Low Latency ToR Switch |
||
The CE6863E-48S6CQ-B is a 1U data center switch that pairs 48 x 25GE SFP28 server ports with 6 x 100GE QSFP28 uplinks. It is built for spine-leaf fabrics, where servers attach at 25GE and every leaf reaches the spine over 100GE. With 4 Tbit/s switching capacity and cut-through forwarding, east-west traffic stays inside the fabric instead of climbing through a slower aggregation layer.
| Model | CE6863E-48S6CQ-B |
|---|---|
| Downlink ports | 48 x 25GE SFP28, 10GE SFP+ compatible |
| Uplink ports | 6 x 100GE QSFP28, 40GE compatible, breakout to 4 x 25GE |
| Switching capacity | 4 Tbit/s |
| Forwarding performance | 2000 Mpps |
| Latency | Under 1 microsecond, hardware cut-through |
| Overlay and fabric | VXLAN, BGP EVPN, M-LAG, PFC, ECN |
| Airflow | Back-to-front, N+1 fan modules |
| Power supply | 1+1 redundant AC or DC, hot swappable |
| Chassis | 1U, 19 inch rack mount |
| Management | NETCONF, YANG, SNMP v1/v2c/v3, sFlow, telemetry streaming |
| Operating system | Huawei VRP, mainstream release preloaded |
| Typical role | Leaf switch for 25GE server access in a two-tier data center fabric |
A: Yes. All 48 SFP28 cages run at 25GE and also accept 10GE SFP+ optics, so a mixed 10GE and 25GE server estate can share the same leaf and be migrated port by port.
A: Yes. The 6 QSFP28 uplink ports accept 40GE and 100GE optics and DAC cables, and a single 100GE port can be split into 4 x 25GE with a breakout cable.
A: Cut-through latency stays in the sub-microsecond range per hop. VXLAN encapsulation adds a small and predictable overhead, so a three-hop leaf-spine path remains in the low single-digit microseconds.
A: It is a common 25GE ToR choice for GPU clusters, because lossless forwarding for RoCE traffic is supported through configurable PFC and ECN on the 25GE and 100GE ports.
Website: https://lonriseeqt.com/
Add: Rm.710, No.1108, Rongmei Rd, Songjiang, Shanghai 201613, China.
Email: yolanda@lonriseequipment.com
Tel: +86-21-37890191 ext.805
WA / Mob / WeChat / Telegram: +86 15021041347
Contact Person: Mrs. Laura
Tel: +86 15921748445
Fax: 86-21-37890191