Model Number: | S5735-S48S4X | Function: | LACP, QoS, SNMP, Stackable, VLAN Support |
---|---|---|---|
Product Part Number: | 02350EXQ | Device Type: | Switch - 48 Ports - Managed |
Communication Mode: | Full-Duplex & Half-Duplex | Transmission Rate: | 10/100/1000Mbps |
Products Status: | Stock | Subtype: | 100 Gigabit Ethernet |
High Light: | S5735-S48S4X Gigabit Access Switches,GE Electrical Downlink Network Switches,10GE Uplink Ports Huawei Network Switches |
Huawei S5735-S48S4X gigabit access switches provide
GE electrical downlink ports and 10GE uplink ports
Technical specifications
Item |
Description |
---|---|
Memory (RAM) | 1 GB |
Flash | 512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) | 66.33 years |
Mean time to repair (MTTR) | 2 hours |
Availability | > 0.99999 |
Service port surge protection | NA |
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (with packaging) | 8.27 kg (18.23 lb) |
Stack ports | Any 100/1000BASE-X ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions) |
RTC | Supported |
RPS | Not supported |
PoE | Not supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) | 89 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) | 67 W |
Operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) | < 61 dB(A) |
Relative humidity | 5% to 95%, noncondensing |
Operating altitude | 0-5000 m (0-16404 ft.) |
Certification |
|
Part number | 98010947 |
S5735-S48S4X appearance
1 |
Forty-eight 100/1000BASE-X ports |
2 |
Four 10GE SFP+ ports Applicable modules and cables:
|
3 | One console port | 4 | One ETH management port |
5 | One USB port | 6 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 |
Ground screw NOTE:
It is used with a ground cable.
|
8 |
Power module slot 1 NOTE:
Applicable power module:
|
9 |
Power module slot 2 NOTE:
Applicable power module:
|
- | - |
Contact Person: Mrs. Laura
Tel: +86 15921748445
Fax: 86-21-37890191