| Part Number: | S5730-36C-HI | Brand: | HUAWEI | 
|---|---|---|---|
| Fixed Ports: | 24 X 10/100/1,000 Base-T , 4 X 10 GE SFP+ | Maximum Power: | 74W | 
| Switching Capacity: | 758 Gbit/s | Condition: | New With 1Year Warranty | 
| Highlight: | gigabit network switch,huawei ethernet switches | ||
 
Huawei S5730-HI gigabit Ethernet switches (hereinafter referred to as the S5730-HI) are Huawei-developed next-generation agile switches that provide fixed full gigabit access and 10 GE uplink interfaces as well as one or two slots for uplink interface extension.
| Item | S5730-36C-HI | 
|---|---|
| Fixed Ports | 24 x 10/100/1,000 Base-T ports, 4 x 10 GE SFP+ ports | 
| Dimensions (W x D x H) | 442 mm x 420 mm x 44.4 mm | 
| Extended Slots | One extended slot, supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card | 
| Input Voltage | AC: Rated AC voltage: 100V to 240V; 50/60 Hz Max. AC voltage: 90V to 264V; 47 Hz to 63 Hz | 
| DC: Rated DC voltage: -48V to -60V Max. DC voltage: -38.4V to -72V | |
| Maximum Power Consumption (without cards) | 74W | 
| Operating Temperature | 0m to 1,800m altitude: 0°C to 45°C 1,800m to 5,000m altitude: The operating temperature reduces by 1ºC for each 220m increase in altitude. | 
| Relative Humidity | 5% to 95% (non-condensing) | 
| Heat Dissipation | Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans | 

| 1 | Twenty-four 10/100/1000BASE-T ports | 2 | Four 10GE SFP+ ports Applicable modules and cables:
			 
 | 
| 3 | One ETH management port | 4 | PNP button NOTICE:
			 To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 
| 5 | One console port | 6 | One USB port | 
| 7 | Ground screw NOTE:
			 It is used with a ground cable. | 8 | ESN label NOTE:
			 You can draw it out to view the ESN and MAC address of the switch. | 
| 9 | SSD card slot NOTE:
			 Pluggable SSD card supported: SSD-240GB | 10 | Rear card slot NOTE:
			 Cards supported:
			 
 | 
| 11 | Fan slot NOTE:
			 Applicable fan module: FAN-028A-B | 12 | Power module slot 2 NOTE:
			 Applicable power modules:
			 
 | 
| 13 | Power module slot 1 NOTE:
			 Applicable power modules:
			 
 | - | - | 
Service features
| Item | Description | 
|---|---|
| MAC Address Table | IEEE 802.1d standards compliance | 
| 256K MAC address entries | |
| MAC address learning and aging | |
| Static, dynamic, and blackhole MAC address entries | |
| Packet filtering based on source MAC addresses | |
| VLAN | 4094 VLANs | 
| Guest VLAN and voice VLAN | |
| GVRP | |
| MUX VLAN | |
| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | |
| VLAN mapping | |
| Wireless Service | AP access control, AP domain management, and AP configuration template management | 
| Radio band management, unified static configuration, and dynamic centralized management | |
| WLAN basic services, QoS, security, and user management | |
| CAPWAP, tag/terminal location, and spectrum analysis | |
| Ethernet Loop Protection | RRPP ring topology and RRPP multi-instance | 
| Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover | |
| SEP | |
| ERPS (G.8032) | |
| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM | |
| STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | |
| BPDU protection, root protection, and loop protection | |
| MPLS | MPLS L3VPN | 
| MPLS L2VPN (VPWS/VPLS) | |
| MPLS-TE | |
| MPLS QoS | |
| IP Routing | Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and routing policy | 
| Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST | 
| Link-type Negotiation Protocol (LNP), similar to DTP | |
| VLAN Central Management Protocol (VCMP), similar to VTP | |
| IPv6 Features | Neighbor Discover (ND) | 
| PMTU | |
| IPv6 Ping, IPv6 Tracert, and IPv6 Telnet | |
| ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types | |
| Multicast Listener Discovery snooping (MLDv1/v2) | |
| IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN | |
| Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave | 
| Multicast forwarding in a VLAN and multicast replication between VLANs | |
| Multicast load balancing among member ports of a trunk | |
| Controllable multicast | |
| Port-based multicast traffic statistics | |
| IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM | |
| MSDP | |
| MVPN | |
| QoS/ACL | Rate limitation in the inbound and outbound directions of a port | 
| Packet redirection | |
| Port-based traffic policing and two-rate three-color CAR | |
| Eight queues on each port | |
| DRR, SP, and DRR + SP queue scheduling algorithms | |
| WRED | |
| Re-marking of the 802.1p and DSCP fields of packets | |
| Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | |
| Queue-based rate limitation and shaping on ports | |
| Security | Hierarchical user management and password protection | 
| DoS attack defense, ARP attack defense, and ICMP attack defense | |
| Binding of the IP address, MAC address, port number, and VLAN ID | |
| Port isolation, port security, and sticky MAC | |
| MAC Forced Forwarding (MFF) | |
| Blackhole MAC address entries | |
| Limit on the number of learned MAC addresses | |
| IEEE 802.1x authentication and limit on the number of users on a port | |
| AAA authentication, RADIUS authentication, and HWTACACS authentication | |
| NAC | |
| SSH V2.0 | |
| HTTPS | |
| CPU protection | |
| Blacklist and whitelist | |
| Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets | |
| Secure Boot | |
| IPSec | |
| ECA | |
| Deception | |
| Reliability | LACP | 
| E-trunk | |
| Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) | |
| ITU-Y.1731 | |
| DLDP | |
| LLDP | |
| BFD for BGP, BFD for IS-IS, BFD for OSPF, and BFD for static route | |
| VXLAN | VXLAN L2 and L3 gateways | 
| Centralized and distributed gateway | |
| BGP-EVPN | |
| Configured through the NETCONF protocol | |
| Super Virtual Fabric (SVF) | The S5730-HI can work as the parent node to vertically virtualize downlink switches and APs as one device for management | 
| A two-layer client architecture is supported | |
| IGMP snooping can be enabled on Access Switches (ASs) and the maximum number of access users on a port can be configured | |
| ASs can be independently configured. Services that are not supported by templates can be configured on the parent | |
| Third-party devices are allowed between SVF parent and clients | |
| iPCA | Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio | 
| Collection of statistics on the number of lost packets and packet loss ratio at network and device levels | |
| TWAMP | Two-way IP link performance measurement | 
| Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter | |
| Management and Maintenance | iStack | 
| Virtual cable test | |
| SNMP v1/v2c/v3 | |
| RMON | |
| Web-based NMS | |
| System logs and alarms of different levels | |
| GVRP | |
| MUX VLAN | |
| 802.3az Energy Efficient Ethernet (EEE) | |
| NetStream | |
| Intelligent O&M | 
Related products
 
AIR-AP18321I-H-K9                                AIR-AP18521-E-K9                          AIR-AP2802I-H-K9
 
AIR-AP-3802I-E-K9                                 AIR-CAP1602I-C-K9                        AIR-CAP2701I-E-K9
 
AIR-CAP3602I-C-K9                               AIR-CT2504-15-K9                           AIR-CT5508-25-K9
AP5030DN AP7030DN AP8030DN
AP8130DN AP6010SN-GN AP2050DN-S
AP6510DN-ASG AP2010DN AP6010-DN
 
 
 
Contact Person: Laura
Tel: 15921748445
Fax: 86-21-37890191